Showing posts with label Building Construction. Show all posts
Showing posts with label Building Construction. Show all posts

Saturday, 21 October 2017

What is Frost Wall? Purpose & Types

Building houses and structures in extreme climates is always a challenge, the temperature depending characteristics of building materials is the sole reason for such a trial. Concrete pouring in hot expands too much and in cold climate contracts too much thereby producing such internal stresses that if not properly taken under-consideration would produce extreme internal strains that might be havoc for the structural integrity and serviceability of the structure. 

What is Frost Wall? Purpose & Types
What is Frost Wall? Purpose & Types

In this post today we will talk about the condition of the soil in freezing weathers and its adverse effect in the form of frost heave and its solution in the form of frost wall. 

Reason why Frost Wall is needed? 

From soil mechanics, it is a well known fact that the matrix of soil particles has voids and gaps that are partially filled by air and water for non-saturated soils. For dry soil (oven dry) the voids are only filled with air while for saturated soils the voids are completely filled by water. Mostly the soil underneath the foundation of the building is soil with partially filled voids by water. This water, during extreme cold climates when the outside temperature falls, freezes and thus producing frost heave. 

Frost heave expands as the ice in the soil accumulates in a structure called ice lens and as we know by the behavior of water; the volume of water increases as it is converted to ice. Thereby, due to conversion and growth of water to ice lens in the soil voids, they push the nearby surrounding soil. The structures having foundation resting on such soils will be shoved upward and thus damaged by the action of ice. The stress reversal occurs after suitable increase in climate and thus thawing might occur relieving the upward shoving of the structure.  

The only remedy for this problem exists in preventing the freezing and heaving of the underneath soil of the foundation. The reason we don’t want the ground to freeze is that frozen ground moves and thus moving the concrete walls up and down. 

What is Frost Wall? 

Frost walls are actually insulating walls that are constructed / placed deep in the ground around the periphery of the foundations beneath the frost line; so that in the cold winters when the ground freezes the walls and the footings are sitting on will not end up with the ground freezing underneath them. 

Sometimes the term frost wall is also referred to the walls placed above ground inside the house for insulation. And sometimes it is also referred to an insulating layer / frost protection of soil placed between house foundation and a wall constructed sufficiently gapped. This type of frost wall only worked for heated structures. This type of frost wall holds heat from the structure in the ground to prevent freezing in areas where ground frost is common.


The frost wall may be load bearing or non-load bearing; in case of load bearing wall the frost wall itself is a foundation wall that takes the foundation deep enough which is below the frost line of that area. In case of non-load-bearing wall it is just an insulating barrio as explained above. The basements in many older homes are not insulated and, therefore, require a frost wall built just inside the basement’s exterior walls to reduce heat loss through the foundation. The interior wall should not touch the exterior wall, and should include a moisture barrier to prevent moist interior air from forming ice inside the wall.

Before the frost wall is fully functional, in case of a basement beneath the building, some preparatory works needs to be done for an effective heat-loss-control phenomenon. For example, basement walls that are made from cinder blocks require the homeowner to patch any open gaps in the mortar with brick filler. Basement walls that are made from poured concrete require the homeowner to patch any cracks with concrete sealer. Once the concrete sealer is applied, the next step is to apply a paint sealer, specialty paint that helps prevent moisture from entering the basement. This is extremely important because the formation of moisture between the frost wall and the basement wall promotes mold growth.

Types of Frost Walls 

Protecting Shallow Foundation with Frost-Protection Insulating 

This type of frost wall is non-load-bearing wall and is meant to protect a building with shallow foundation when deep foundation is not-economical or not-feasible. The wall constructed after leaving a sufficient gap with the building foundation would prevent the soil from losing heat. In such a type of frost wall, the soil surround a building’s foundation would warm up by the heat that is radiated from the building.

Protecting Shallow Foundation with Frost-Protection Insulating
Protecting Shallow Foundation with Frost-Protection Insulating 


A layer of rigid foam insulation is applied vertically to the outside of the foundation wall, and another layer of rigid insulation is placed horizontally under the soil at the base of the foundation wall. These layers of insulation direct the warmth from the heated interior of the building downward into the soil and keep it there so that the soil does not freeze.

Frost-protection wall for non-heated Buildings


Frost wall of type 1 explained above is only applied for a heated building as in such a frost-protected wall the warmth radiated by building is the only source of heat. But for unheated buildings such a type of frost wall will not work.

Frost-protection wall for non-heated Buildings
Frost-protection wall for non-heated Buildings

An alternative design would be to use the heat of the temperature of deeper layers of earth which is always around 40 to 50 degrees throughout the year. In this design, a horizontal layer of insulation is laid under the building's entire foundation and extends outward from the foundation, but there is no vertical insulation. 

The layer of insulation rests on a layer of gravel. The warmth of the soil is stored and radiated upward, preventing the upper layers of soil from freezing.

Cost

Although for the cost, it depends on the design, but usually it is not an expensive structure and keeping the long-term benefits in view the economy is not the decisive factor whether to build it or not. Usually they are a 4 ft high concrete wall sitting on a footing. Usually they do not require water proofing or structural steel, this is because they are back-filled on each side in your walkout basement. 




Thursday, 19 October 2017

What is Efflorescence? Causes, Prevention and Removal Techniques

The brick masonry industry is plagued with a stubborn and persistent confusing delinquent trouble frequently seen as white powdery scum on a lot of buildings. This white powdery substance is termed as efflorescence which is, although, not well understood but still the masonry industry is still able to define it, knows where it comes from and also methods to reduce and prevent this badly-behaved nature in brick masonry have been device and practiced these days.  

Sure Ways to Prevent and Cure Efflorescence


According to dictionaries the efflorescence is defined as:- 

A change on the surface to a powdery substance upon exposure to air, as a crystalline substance through loss of water.
To become encrusted or covered with crystals of salt or the like through evaporation or chemical change.
Actually efflorescence is a deposit of water-soluble salts that are left on the surface of masonry as a crystalline powder sometimes white or brown or green or yellow after the water evaporates from the exterior surfaces upon exposure. You might have not seen any color other than white but still it exists depending on the type of salts etc. 

This is a prominent defect in brick masonry. In moist climate, in damp places, like basements or under leaky gutter, masonry often gets disfigured. Deposit originates from the mortar and frequently spreads over a part or entire face of the wall. 

Absorbed water dissolves the salts of sodium, potassium and evaporating, forms a crystalline deposit on the surface. In addition to unsightly appearance, the crystallization of salts in the pores of the bricks or mortar may cause disruptive expansion resulting in disintegration due to cracking. 

The problem of efflorescence is not new; its existence finds its way back in the prehistoric primitive times as the brick masonry was ever started and great piece of time, money and efforts have been made and spent trying to solve the difficulties generated by this persevering problem.  

The timing of when the efflorescence appears is very critical, it open appears just after the completion of the structure and is thus named as “new building bloom”.  And at this time the contractor, builder or architect are mostly concerned with the appearance of the new structure. The appearance of efflorescence is triggered by variation of temperature and is obvious during the winter, but may also be observed throughout the year following heavy rains and sudden drops in temperature.  In summer, even after prolonged periods of rain, moisture evaporates so quickly that only small amounts of salt are transported to the surface. However, during winter, slower rates of evaporation lead to migration of salts to the surface. 

This article will explain in detail about the sources of the efflorescence, how it works, about the attempts that are to be made in order to reduce its destructive effects and if it does appear the ways to remove it.

Sources and Causes of Efflorescence  

In most general cases, the efflorescence is caused when the water gets mixed with masonry material and thus moving the salts to the surface and usually the free salts were created. In other cases when the free salts are readily available the free water dilutes it into a solution which is transported through brick masonry depositing it on the surface referred as efflorescence. 

During detailed analysis of the efflorescence it was found that sometimes the salts which are deposited inside the brick masonry form a crystal depositing within the matrix of masonry called crytoflorescenc as it is not visible. 

Conditions for Efflorescence 


The subject of efflorescence is not that simple, it is a confusing mechanism and the real cause is hard to find sometimes. However, it is well known that there are three conditions that must be met in order for the efflorescence to appear. 

  • First: There must be water-soluble salts present somewhere in the wall
  • Second: There must be sufficient moisture in the wall to render the salts into a solution
  • Third: there must be a path for the soluble salts to migrate through to the surface where the moisture can evaporate, thus depositing the salts which can crystallize and cause efflorescence. 

These three conditions must be simultaneously existed in any structure for the appearance of the efflorescence which means if any one of the cases does not exists than no efflorescence will appear. 
Although the efflorescence is a complex problem, the prevention is not that difficult with economic and feasible steps there exists ways to reduce any one of the cases/conditions required and is thus making nearly impossible for efflorescence to occur. 

Sources of Salts 

The chemical reason and nature of efflorescence is very complex as there are many chemicals in the clay bricks, concrete blocks, mortar used, cement, lime, sand, admixture and ground water that can cause sulfates, carbonates, sodium bicarbonate or silicate to cause efflorescence. The efflorescence in green color which is often termed as “Green Stain” is a result of certain vanadium and molybdenum compounds present in some ceramic brick units. Similarly in brown color the efflorescence called “Brown stain” exists which is due to manganese deposits. 

 The appearance of efflorescence is generally not dependent on the quantity present of the water soluble salts as it is reported that even very small quantities of water soluble salts causes efflorescence.  Sodium and potassium hydroxides are commonly present in Portland cements which may cause some efflorescence during the first year after construction. This is known as “Building-bloom”, a condition which typically disappears after a short while. 


Moisture 

If your house/building you are constructing is in areas of high annual rainfall than it must be considered in the initial stages and planning of project that the materials will be subjected to higher quantities of water both during and after construction making it more susceptible and liable for efflorescence. Similarly even if the rainfall is not more, the area is near sea where humidity is always more than in such areas the projects are also greater exposed for efflorescence potential. 

As water is always needed for the salt to dissolve, which means if more water exists the more solution will be prepared and thus more salt will dissolve causing more efflorescence. 

So after discussing sources and reasons of efflorescence we can conclude that detailed study of the following items is necessary for judging the reason and prevention measures for the efflorescence :- 

1. Moisture 
2. Construction Material
3. Temperature

Preventive and Controlling measures 

Since many factors influence the formation of efflorescence, it is difficult to predict if and when any will appear: There is no accepted standard test method for   reassuring the efflorescence potential of masonry mortar. Several experimental methods have been proposed, but none has been accepted as effectively predicting the performance of mortar materials in actual use.

After finding the reasons and causes of the efflorescence it will be easy for the one to control it prior to avoid the situation to get worsen. Even if the soluble alkali sulfates exist in a masonry wall, before the sulfates can cause efflorescence the salts must be dissolved into solution by water. If no moisture reaches the sulfates than they cannot be rendered into solution and migrate to the surface where the water will evaporate, leaving the sulfates salts on the surface to crystallize and become efflorescence. Attention must be given to preventing any soluble alkaline sulfates from being rendered into solution by water. 

This is difficult since during construction water is naturally used in the mortar and grout; therefore the amount of water in the wall should be controlled to only reduce the amount necessary for actual construction. The majority of the water is absorbed into the masonry and used to chemically react with the Portland cement and hydrated   me and is thus not free water.

To avoid Efflorescence do not use porous bricks in contact with limestone. Protect brickwork against contamination of salt-bearing materials during building operations. Bricks should be thoroughly soaked during construction. Correct design of DPC should be used.

Once the cause of efflorescence is corrected, the removal of the deposit is relatively easy, since most efflorescing salts are water soluble. In general, efflorescence can be removed by dry-brushing followed by flushing with clean water. If this is not satisfactory, walls can be washed with a five to ten percent solution of muriatic acid. It is always advisable that a small inconspicuous test area be tried first to determine whether etching or other discoloring will occur. After the acid treatment, the surface should be immediately and thoroughly flushed with clean water.

To summarize, three conditions must exist before efflorescence can occur. If these three conditions can be controlled, there should be no efflorescing of masonry walls.

1. Reduce all soluble alkali sulfates.
2. Use good details to prevent water from entering the masonry.
3. Use good construction practices to eliminate migratory paths for moisture.

Remember, it is very difficult to totally control any one of these three conditions, but it is relatively simple to reduce the effect each one has towards efflorescence. The following 5 simple ways are a sure way towards efflorescence free brick / block masonry for your project. 

1. Limit Driving Moisture Force
2. Provide for good drainage
3. Construct good mortar joints
4. Ensure proper curing
5. Limit Water Entry